Description: IOT Standard Stacker Full Cause: Output Tray Full is Detected.
Remedy: 1 • Check the shapes of the ACTUATOR FULL STACK • Do the ACTUATOR FULL STACK move smoothly? Do they have any damage? Replace the ACTUATOR FULL STACK. Go to Step 2. 2 • Execute the Diag Digital Input 071-122 to check the operation of the FULL STACK SENSOR. • Is the FULL STACK SENSOR operating normally? Replace (MCU PWB) 1 • Check the connection between the FULL STACK SENSOR and the MCU PWB. • Is the EXIT SENSOR HARNESS ASSEMBLY (P/J272 - P/J27) connected securely? Go to Step 2. Securely connect the EXIT SENSOR HARNESS ASSEMBLY 2 • Replace the EXIT SENSOR HARNESS ASSEMBLY. • Does an error occur? Go to Step 3. Troubleshooting complete. 3 • Replace (Full Stack Sensor). • Does an error occur? Replace (MCU PWB) Troubleshooting complete.