Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 042-313 — Xerox WorkCentre 3615

Code: 042-313

Description: LVPS Fan Motor Failure Cause: MCU detects an error upon receiving error signal from the LVPS Fan.
Remedy: 1 • Execute the Diag Digital Output [042- 003] to check the rotation of the LVPS FAN. • Is it working properly? Replace (MCU PWB) Go to Step 2. 2 • Check the installation of the LVPS FAN. • Manually rotate the LVPS FAN. Is there any resistance? Reinstall the LVPS FAN properly Go to Step 3. 3 • Check the connection between the LVPS FAN and LVPS, as well as between the LVPS PWB and MCU PWB. • Are the LVPS FAN and the LVPS HARNESS ASSEMBLY connected securely? Go to Step 4. Securely connect the LVPS FAN and the LVPS HARNESS ASSEMBLY 4 • Replace the LVPS FAN. PL Does an error occur? Go to Step 5. Troubleshooting complete. 5 • Replace the LVPS HARNESS ASSEMBLY. • Does an error occur? Go to Step 6. Troubleshooting complete. 6 • Replace (LVPS). • Does an error occur? Replace (MCU PWB) Troubleshooting complete.