Description: 062-277: IIT internal communication error. 062-311: IIT failure initialization error. 062-317: Interference buffer full was detected at the time of DADF scan. 062-318: A Scan setup did not meet the deadline into Page Gap. 062-319: A PLL lock was not carried out before 1stScan start, but the lock has separated during continuation. 062-320: Scanning error. 062-321: Unexecutable error. (carriage is at the locked position, etc.) 062-322: Parameter error. 062-360: Carriage home position error. 062-371: IIT failure Lamp error. 062-393: CCD ASIC communication error.
Remedy: 062-277/062-311/062-317/062-318/062-319/062-321/062-322/062-360/062-371/062-393: • Turn the power Off and On to check that the error recurs. Then proceed to the FIP. 062-320: 1. Check the file data in the printer. Print or clear the stored files and data at the printer memory. 2. Perform a black and white scan. 3. If the error occurs again, proceed to the FIP. 1 Check the connection between the IIT ASSEMBLY and the ESS PWB. • Are the P/J451 and the P/J452 connected securely? Go to Step 2. Connect that P/J451 and P/J452 are secure 2 • Replace (IIT Assembly). • Does an error occur? Replace (ESS PWB) Troubleshooting complete.