Description: 077-106 Exit On Jam 077-108 Exit Off early Jam 077-109 Exit Off Jam Cause: 077-106: Either of the following error codes is displayed in the UI. 050-130 - 050-132 - 050-142 The Exit Sensor does not turn ON within the specified time after the Regi Clutch turned On. 077-108: 050-130 is displayed in the UI. After the Exit Sensor turned ON, the Exit Sensor turned OFF before the specified time. 077-109: 050-130 is displayed in the UI. After the Regi. Sensor turned OFF, the Exit Sensor did not turn OFF within the specified time.
Remedy: 1 • Is there any foreign substances or bits of paper found on the paper transport path? Note: Make sure that the FUSING ASSEMBLY has cooled down before performing the operation. Remove the foreign substances and bits of paper, etc. Go to Step 2. 2 Are the paper feed rolls installed properly? Go to Step 3. Reinstall the corresponding paper feed rolls 3 Are the paper feed rolls deformed or worn out? Replace the corresponding paper feed rolls Go to Step 4. 4 • Execute the Diag Digital Input [071-103] to check the operation of the EXIT SENSOR. • Is the EXIT SENSOR operating normally? Go to Step 5. Go to FIP 2.01 5 • Execute the Diag Digital Input [071-102] to check the operation of the REGISENSOR HVPS. • Is the REGI-SENSOR HVPS operating normally? Go to Step 6. Go to FIP 2.03 6 • Execute the Diag Digital Output [071-007] to check the operation of the EXIT CLUTCH ASSEMBLY. • Is the EXIT CLUTCH ASSEMBLY operating normally? Go to Step 7. Go to FIP 2.08 7 • Execute the Diag Digital Output [071-006] to check the operation of the REGI. CLUTCH. • Is the REGI. CLUTCH operating normally? Go to Step 8. Go to FIP 2.10 8 • Execute the Diag Digital Output [071-001] to check the rotation of the MAIN DRIVE ASSEMBLY. • Is it working properly? Replace (MCU PWB) Go to FIP 2.15