Code: 12-300
Description: Finisher Jam 5 RAP 12-300 The trail edge of the document failed to deactuate the exit sensor within the correct time.
Remedy: 1. Remove all jammed documents from the finisher. 2. Check that the exit sensor actuator, PL 12.20 Item 3 moves freely and is not damaged. NOTE: If necessary, remove the finisher to check the exit sensor actuator. Refer to REP 12.1. 3. Enter dC330 code 12-805. Check the exit sensor (Q12-805), PL 12.20 Item 7. 4. Check the wiring between the exit sensor and J7 on the Finisher PWB. If necessary, install a new exit sensor, PL 12.20 Item 7. 5. Enter dC330 code 12-110. Check that the exit motor (MOT12-110), PL 12.20 Item 10 runs and drives the exit roll, PL 12.20 Item 1. 6. Check the wiring between the exit motor and J5 on the Finisher PWB. 7. Check the drive belt, PL 12.20 Item 12. If necessary, install a new drive belt. 8. Check that the exit roll, PL 12.20 Item 1 and exit roll idlers, PL 12.20 Item 6 are clean and rotate freely. If necessary, install a new exit roll, PL 12.20 Item 1. 9. Check that the finisher PWB DIP switch settings are correct. Refer to the 12A Finisher PWB DIP Switch Settings RAP. 10. If necessary, install new components: • Exit motor, PL 12.20 Item 10. • Finisher PWB, PL 12.10 Item 8.