Code: 04-200, 04-300, 04-400
Description: Tray 2, 3 or 4 Elevating Error RAP 04-200 The tray 2 stack height sensor did not actuate within 13 seconds of the tray 2 elevating motor start. 04-300 The tray 3 stack height sensor did not actuate within 13 seconds of the tray 3 elevating motor start. 04-400 The tray 4 stack height sensor did not actuate within 13 seconds of the tray 4 elevating motor start.
Remedy: 1. Make sure that the tray is fully home. 2. Pull out the tray. Check for obstructions behind the tray. 3. Check the tray elevator mechanism on the back of the tray. 4. Check that the stack height sensor actuator on the feed head, PL 8.10 Item 5 is not missing or damaged. If necessary, install a new tray feed assembly, PL 8.10 Item 1. 5. Enter dC330. Check the relevant tray stack height sensor, PL 8.10 Item 2: • Tray 2. Code 07-250. • Tray 3. Code 07-350. • Tray 4. Code 07-450. 6. Check the wiring between the tray stack height sensor and CN7 on the Tray PWB. If necessary, install a new stack height sensor, PL 8.10 Item 2. 7. Check the tray up limit switch, PL 8.10 Item 17. NOTE: There are no component control codes to check the tray up limit switch. 8. Enter dC330. Check the relevant tray elevating motor, PL 7.20 Item 7. • Tray 2. Code 04-520. • Tray 3. Code 04-530. • Tray 4. Code 04-540. 9. Check the wiring between the tray up limit switch and the tray elevating motor, PL 7.20 Item 7 and CN7 on the Tray PWB. If necessary, install a new tray up limit switch, PL 8.10 Item 17. 10. Check the wiring between CN1 on the Tray PWB and CN24 on the Main PWB. 11. If necessary, install new components: • Tray elevating motor, PL 7.20 Item 7. • Main PWB, PL 1.10 Item 1. • Tray cassette, PL 7.10 Item 1.