Mã lỗi 062-371, 062-380 — Xerox WorkCentre 5019

Code: 062-371, 062-380

Description: Lamp Illumination Fail/ AGC Fail [Lamp Illumination Fail] Insufficient light from Lamp detected in CCD. (During white gradation correction/AGC before Scan starts) [AGC Fail] Insufficient lamp brightness was detected when performing AGC.
Remedy: Check whether there is something blocking the light and check the Lamp, Lens, Mirror, and White Color Correction Plate for deterioration or contamination.
1. Turn ON the power and enter the Diag mode. Change the value for NVM [715-030] to '1' and then perform [NVM Write]. 2. A 3 or 4-digit number is displayed in the current value column. 3. Check the upper 1 or 2 digits, or the lower 2 digits using the following table and replace the appropriate parts. Sample Display • 110 (3-digit display): LED Lamp failure and LED Lamp Flexible Flat Cable is damaged or has poor contact. (The first digit '1' in '110' is the upper digit, which indicates the LED Lamp ('0' in '01' is not displayed). The lower 2 digits '10' indicates the LED Lamp Flexible Flat Cable.) • 1000 (4-digit display): The LED Lamp Flexible Flat Cable is damaged or has poor contact. (The first 2 digits '10' in '1000' are the upper digits, which indicates the LED Lamp Flexible Flat Cable. The lower 2 digits '00' indicates that nothing is applicable (no failures).) NOTE: Perform IIT diagnostic and then call NVM [715-030] again (press the Change Settings button) to check the value (diagnostic result). 4. After replacing the appropriate parts, again change the value for NVM [715-030] to '1' and then perform 'NVM Write'. 5. Check that the current value column becomes '0'. 6. If the problem persists after performing the above procedure, check the following: • Check for burnt out LED Lamp (DC330 [062-002]). (PL 1.5) • Check the Flat Cable between the LED Lamp PWB J7002 and the IIT Carriage J7001 for open circuits, short circuits, and poor contacts (especially, check whether the Flat Cable was inserted in a skewed manner). • Check the Flat Cable between the IIT Carriage J700 and the ESS/MCU PWB J420 for open circuits, short circuits, and poor contacts (especially, check whether the Flat Cable was inserted in a skewed manner). 7. If no problem is found, replace the ESS/MCU PWB. (PL 18.1)

← Xem tất cả mã lỗi Xerox WorkCentre 5019

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie