Description: ATC Amplitude Fail/ ATC Average Fail [ATC Amplitude Fail] The output amplitude of the ATC Sensor in the ATC (Automatic Toner Control) measurement is small. [ATC Average Fail] The average output value is not within the specified range in the ATC (Automatic Toner Control) measurement.
Remedy: 1. Install a Toner Cartridge that contains Toner. Copy a Test Chart (499T 00247), etc. and check whether the density has recovered. 2. Check the Toner Dispense Motor (Output Check [092-001]) for operation failure. (PL 8.2) 3. Check the Toner transport path for Toner blockage. 4. Check the connection between the ATC Sensor (Drum Cartridge) P615 and the ESS/ MCU PWB J409 for open circuit, short circuit, and poor contact. 5. If no problem is found, replace the following parts in sequence: • Drum Cartridge (PL 8.1) • ESS/MCU PWB (PL 18.1)