Code: E6-2
Description: STM L/H Cover open. Access Cover 2 is open.
Remedy: I/O Diagnostic Codes [01-10] STM Interlock Switch
Check Items: • Check that Access Cover 2 closes correctly. • Check that the STM Interlock Switch is correctly installed and that the electrical connection is good. • Check that the following wires are connected securely with good electrical contact. If there is no problem, replace the STM Interlock Switch (PL 11.5). – Wire between STM Interlock Switch J173-2 ( P/J173) and STM PWB J542-9 ( P/J542) – Wire between STM Interlock Switch J173-1 and STM PWB J542-10 • Replace the STM PWB (PL 11.5) , the LVPS (PL 8.1) , and the AIOC PWB (PL 8.1) in that order.
Check Items: • Check that Access Cover 2 closes correctly. • Check that the STM Interlock Switch is correctly installed and that the electrical connection is good. • Check that the following wires are connected securely with good electrical contact. If there is no problem, replace the STM Interlock Switch (PL 11.5). – Wire between STM Interlock Switch J173-2 ( P/J173) and STM PWB J542-9 ( P/J542) – Wire between STM Interlock Switch J173-1 and STM PWB J542-10 • Replace the STM PWB (PL 11.5) , the LVPS (PL 8.1) , and the AIOC PWB (PL 8.1) in that order.