Code: C8-1
Description: F/O#1 SNR Static JAM. Tray1 Feed Sensor ON is detected during standby.
Remedy: I/O Diagnostic Codes [08-07] Tray1 Feed Sensor
Check Items: • Tray1 Feed Sensor dirty and Sensor Actuator deformed or damaged • Foreign matter, burrs, or paper in the paper path • Check that the following wires are connected securely with good electrical contact. If there is no problem, replace the Tray 1 Feed Sensor (PL 2.5) . – Wire between Tray 1 Feed Sensor J158-3 ( P/J158) and STM PWB J501-6 ( P/J501) – Wire between Tray 1 Feed Sensor J158-2 and STM PWB J501-7 – Wire between Tray 1 Feed Sensor J158-1 and STM PWB J501-8 • Replace the AIOC PWB (PL 8.1) .
Check Items: • Tray1 Feed Sensor dirty and Sensor Actuator deformed or damaged • Foreign matter, burrs, or paper in the paper path • Check that the following wires are connected securely with good electrical contact. If there is no problem, replace the Tray 1 Feed Sensor (PL 2.5) . – Wire between Tray 1 Feed Sensor J158-3 ( P/J158) and STM PWB J501-6 ( P/J501) – Wire between Tray 1 Feed Sensor J158-2 and STM PWB J501-7 – Wire between Tray 1 Feed Sensor J158-1 and STM PWB J501-8 • Replace the AIOC PWB (PL 8.1) .