Code: U1-1
Description: Main Motor Rotation Error. 500 ms after the IOT Motor starts, the IOT Motor Lock signal is Low.
Remedy: Close the Left Hand Cover and the Front Cover. Execute diagnostics [04--01 Main Motor On]. The IOT Motor can be heard rotating. Y↓N→Check P/J504 and P/J201. Both P/J504 and P/J201 are connected securely. Y↓N→Connect P/J504 and P/J201 securely. Measure the voltage between LVPS PWB P504-1 ( P/J504) (+) and GND (-). The voltage is approximately +24VDC. Y↓N→Replace the LVPS (PL 8.1). Check the wire between J504-3 ( P/J504) and J201-3 ( P/J201). The wire is not shorted or open. Y↓N→Repair the wire. Replace the IOT Motor (PL 1.1) and the AIOC PWB (PL 8.1) in that order. Check the installation of the IOT Motor (PL 1.1 ) . The IOT Motor is installed properly. Y↓N→Install the IOT Motor (PL 1.1 ) properly. Turn the rotor of the IOT Motor (PL 1.1 ) counterclockwise by hand. It rotates smoothly, without any abnormal load. Y↓N→Check for any foreign substances that obstruct the drive and for any incorrectly installed parts. There are foreign substances or incorrectly installed parts. Y↓N→Replace the IOT Motor (PL 1.1) . Remove any foreign substances and fix any installation errors. Check the wire between J504-3 ( P/J504) and J201-3 ( P/J201). The wire is not shorted or open. Y↓N→Repair the wire. Replace the IOT Motor (PL 1.1) and the AIOC PWB (PL 8.1) in that order.