Code: U4-1
Description: Fuser On Time Fail. • The lamp did not turn OFF within the specified time after turning ON. • Or, Warm Up was not completed within the specified time after power ON.
Remedy: When U4-1 occurs, [NVM 50-20 FSR Reset FuserOverTemp] becomes "3." Run [NVM 50-20 FSR Reset FuserOverTemp] using "0" to reset it. Check to see if there is paper in the Fuser. The Fuser is normal and there is no paper in it. Y↓N→Remove the paper. Check the condition of the Fuser. The Fuser is installed properly. Y↓N→Install the Fuser properly. Remove the Fuser. Check the conductivity between the Thermostat contacts. The contacts are conductive. Y↓N→Replace the Fuser (PL 5.1) . Check the Heater Rod for an open circuit. There is no open circuit between J600-1 ( P/ J600) and J600-2. Y↓N→Replace the Fuser (PL 5.1) . Check the resistance of the Thermistor. There is no open circuit between J601-1 ( P/J601) and J601-2, and the resistance is a minimum of 228k ohms (cold). Y↓N→Replace the Fuser (PL 5.1) . Immediately after Main Switch ON, the voltage between J3-3 ( P/J3) (ACH) and J3-1 (ACN) is approximately 200VAC. Y↓N→Replace the LVPS (PL 8.1) . Check the wire between J408 ( P/J408) and P601 ( P/J601). The wire between J408 and P601 is not shorted or open. Y↓N→Repair the wire. Check the wire between J3 ( P/J3) and P600 ( P/J600). The wire between J3 and P600 is not shorted or open. Y↓N→Repair the wire. Replace the Fuser (PL 5.1) , the LVPS (PL 8.1) , and the AIOC PWB (PL 8.1) in that order.