Code: U4-9
Description: Fuser Fan Defect. After the start of Fan Fail Signal monitoring, the signal level was Low not more than 30 times.
Remedy: Turn the power ON. Visually check the NOHAD Fan (PL 9.2). The NOHAD Fan is rotating. Y↓N→Measure the voltage between the AIOC PWB P405-3 ( P/J405) (+) and GND (-). The voltage is approximately +24VDC. Y↓N→Replace the AIOC PWB (PL 8.1) . Replace the NOHAD Fan (PL 9.2) and the AIOC PWB (PL 8.1) in that order. Measure the voltage between the AIOC PWB P405-2 P/J405 (+) and GND (-). The voltage is 0. Y↓N→Replace the NOHAD Fan (PL 9.2) and the AIOC PWB (PL 8.1) in that order. Replace the AIOC PWB (PL 8.1) .