Description: DADF Regi Sensor Off Jam/ DADF Regi Sensor Off Jam on Inverting [DADF Regi Sensor Off Jam] After the DADF Pre Regi Sensor turned OFF at Scan operation, the DADF Regi Sensor did not turn OFF within the specified time. [DADF Regi Sensor Off Jam on Inverting] After the DADF Pre Regi Sensor turned OFF at Invert operation, the DADF Regi Sensor did not turn OFF within the specified time.
Remedy: Check the following: • Transportation failure due to foreign substance on the document path. • The surface of the Regi Roll, Out Roll, and Exit Roll for foreign substances. • The surface of the Regi Roll, Out Roll, and Exit Roll for wear. • The DADF Regi Sensor (Input Check [005-110]) for operation failure. (PL 56.14) • The DADF Pre Regi Sensor (Input Check [005-206]) for operation failure. (PL 56.14) • The DADF Feed Motor (Output Check [005-008]) for operation failure. (PL 56.6) • The Drive Gear for wear and damage. If no problem is found, replace the DADF PWB. (PL 56.2)