Description: Tray 1 Paper Size Switch Broken The Tray 1 Size Sensor open circuit was detected. (The AD value is at its largest.) NOTE: If this is already detected, it will be displayed on the UI Panel when a Job is being performed.
Remedy: Check the following: • The connection between the Tray 1 Paper Size Switch J109 and the ESS/MCU PWB J414 for open circuit, short circuit, and poor contact. • Tray 1 Paper Size Switch: Analog Monitor [072-050]/Input Check [072-114] (PL 9.1) • The Tray 1 paper guide mechanism for damage and foreign substances. • The Tray 1 Paper Size Switch for damage, improper installation, and Actuator operation failure. If no problems are found, replace the ESS/MCU PWB (PL 18.3).