Description: CVT Feed Sensor On JAM RAP After the first-out feed operation started (Feed Motor On (CW)) in Duplex mode, the DADF Feed Out Sensor did not turn On within the specified time.
Remedy: Execute Component Control[005-205]. Actuate the DADF Feed Out Sensor (PL 15.6) with paper. The display changes. Y↓N→Check the connections of P/J769 and P/J758. P/J769 and P/J758 are connected correctly. Y↓N→Connect P/J769 and P/J758. Check the wire between J769 and J758 for an open circuit or a short circuit. The wire between J769 and J758 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P758-1 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P758-3 (+) and GND (-). Actuate the DADF Feed Out Sensor with paper. The voltage changes. Y↓N→Replace the DADF Feed Out Sensor (PL 15.9). Replace the DADF PWB (PL 15.3). Execute Component Control[005-001]. The DADF Feed Motor (PL 15.9) starts up. Y↓N→Check the connections of P/J764 and P/J754. P/J764 and P/J754 are connected correctly. Y↓N→Connect P/J764 and P/J754. Check the wire between J764 and J754 for an open circuit or a short circuit. The wire between J764 and J754 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB (PL 15.3) P754-1 (+) and GND (-), and between P754-7 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the DADF PWB (PL 15.3). Replace the DADF Feed Motor (PL 15.9). If the problem persists, replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).