Description: CVT Invert On JAM 2 RAP After the Read Speed Control operation started (Registration Motor On (CCW)), the Invert Sensor did not turn On within the specified time.
Remedy: Execute Component Control[005-211]. Actuate the DADF Invert Sensor (PL 15.7) with paper. The display changes. Y↓N→Check the connections of P/J780 and P/J761. P/J780 and P/J761 are connected correctly. Y↓N→Connect P/J780 and P/J761. Check the wire between J780 and J761 for an open circuit or a short circuit. The wire between J780 and J761 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P761-7 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P761-9 (+) and GND (-). Actuate the DADF Invert Sensor with paper. The voltage changes. Y↓N→Replace the DADF Invert Sensor (PL 15.7). Replace the DADF PWB (PL 15.3). Execute Component Control[005-026]. The DADF Registration Motor (PL 15.9) starts up. Y↓N→Check the connections of P/J765 and P/J755. P/J765 and P/J755 are connected correctly. Y↓N→Connect P/J765 and P/J755. Check the wire between J765 and J755 for an open circuit or a short circuit. The wire between J765 and J755 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB (PL 15.3) P755-1 (+) and GND (-), and between P755-6 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the DADF PWB (PL 15.3). Replace the DADF Registration Motor (PL 15.9). If the problem persists, replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).