Description: DADF Nudger Lift Up Failure RAP After the DADF Nudger Motor started reverse rotation, the DADF Nudger Sensor did not turn On within the specified time.
Remedy: Manually operate the Feed Head mechanism. The Feed Head mechanism moves smoothly. Y↓N→Replace the parts that are interfering with operation. Execute Component Control[005-225]. Actuate the DADF Nudger Sensor with paper. The display changes. Y↓N→Check the connections of P/J788 and P/J786. P/J788 and P/J786 are connected correctly. Y↓N→Connect P/J788 and P/J786. Check the wire between J788 and J786 for an open circuit or a short circuit. The wire between J788 and J786 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P786-7 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P786-9 (+) and GND (-). Actuate the DADF Nudger Sensor with paper. The voltage changes. Y↓N→Replace the DADF Nudger Sensor (PL 15.5). Replace the DADF PWB (PL 15.3). Execute Component Control[005-090]. The DADF Nudger Motor (PL 15.6) can be heard. Y↓N→Check the connections of P/J787 and P/J786. P/J787 and P/J786 are connected correctly. Y↓N→Connect P/J787 and P/J786. Check the wire between J787 and J786 for an open circuit or a short circuit. The wire between J787 and J786 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB (PL 15.3) P786-1 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the DADF PWB (PL 15.3). Replace the DADF Nudger Motor (PL 15.6). If the problem persists, replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).