Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 010-398 — Xerox WorkCentre 5230

Code: 010-398

Description: Fuser Lock Failure RAP The Fuser Fan failed
Remedy: Turn on the power. Visually check the rotation of the Fuser Fan. The Fuser Fan is rotating. Y↓N→Measure the voltage between the MCU PWB P/J408-2 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the MCU PWB (PL 9.1). Check the wire between P/J214-13 and P/J408-2 for an open circuit or a short circuit. The wire between J214-13 and J408-2 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the Main Drive Assembly CN102-3 (+) and CN102-2 (-). The voltage is +24VDC. Y↓N→Replace the Main Drive Assembly (PL 1.1). Replace the Fuser Fan (PL 4.2). Measure the voltage between the MCU PWB P/J408-1 (+) and GND (-). The voltage is approx. 0VDC. Y↓N→Measure the voltage between the Main Drive Assembly CN102-1 (+) and GND (-). The voltage is approx. 0VDC. Y↓N→Replace the Fuser Fan (PL 4.2). Check the wire between P/J214-14 and P/J408-1 for an open circuit or a short circuit. The wire between J214-14 and J408-1 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Replace the Main Drive Assembly (PL 1.1). Replace the MCU PWB (PL 9.1).