Code: 012-151
Description: Compile Exit Sensor Off JAM RAP After the Compile Exit Sensor turned On, the Compile Exit Sensor did not turn Off within the specified time.
Remedy: Check the Transport Roll for wear and paper powder. The Transport Roll is ok. Y↓N→Replace the Transport Roll. Check for foreign substances, distortion and paper powder in the paper transport path. No distortion, foreign substances, or paper powder are found in the paper transport path. Y↓N→Clear away the foreign substances and paper powder. Correct the distortion. Execute Component Control[012-150 Compile Exit Sensor]. Actuate the Compile Exit Sensor with paper. The display changes. Y↓N→Check the connections of J8869 and P/J8988. J8869 and P/J8988 are connected correctly. Y↓N→Connect J8869 and P/J8988. Check the wire between J8869 and J8988 for an open circuit or a short circuit. The wire between J8869 and J8988 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the Finisher PWB P8988-6 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the Finisher PWB (PL 23.16). Measure the voltage between the Finisher PWB P8988-5 (+) and GND (-). Actuate the Compile Entrance Sensor with paper. The voltage changes. Y↓N→Replace the Compile Entrance Sensor (PL 23.14). Replace the Finisher PWB (PL 23.16). Execute Component Control[012-038 Transport Motor ON]. The Transport Motor can be heard. Y↓N→Check the connections of P/J8879 and P/J8983. P/J8879 and P/J8983 are connected correctly. Y↓N→Connect P/J8879 and P/J8983. Check the wire between J8879 and J8983 for an open circuit or a short circuit. The wire between J8879 and J8983 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the resistance of the Transport Motor (PL 23.13) wires between each point of J8879-1/2/5/6. The resistance is approx. 20Ohm. Y↓N→Replace the Transport Motor (PL 23.13). Measure the voltage between each point of the Finisher PWB (PL 23.16) P8983-9/10/11/ 12 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the Finisher PWB (PL 23.16). Replace the Transport Motor (PL 23.13). If the problem persists, replace the Finisher PWB (PL 23.16). Replace the Finisher PWB (PL 23.16).