Code: 012-295
Description: Staple Move Sensor On Failure RAP • After the Stapler started moving to the Staple Position and the Stapler Move Position Sensor turned Off, the Staple Move Sensor did not turn On within 2sec. • After the Stapler completed moving to the Staple Position, the Stapler Move Position Sensor did not turn On.
Remedy: Execute Component Control[013-144 Stapler Move Position Sensor]. Actuate the Staple Move Position Sensor with paper. The display changes. Y↓N→Check the connections of J8898 and J8891, P/J8994 and J8985. The connectors are connected correctly. Y↓N→Connect the connectors. Check the wire between J8898 and J8985 for an open circuit or a short circuit. The wire are conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the Finisher PWB P8891-6 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the Finisher PWB (PL 23.16). Measure the voltage between the Finisher PWB P8985-5 (+) and GND (-). Actuate the Staple Move Position Sensor with paper. The voltage changes. Y↓N→Measure the voltage between the Booklet PWB p8991-2 (+) and GND (-). Actuate the Staple Move Position Sensor with paper. The voltage changes. Y↓N→Replace the Staple Move Position Sensor (PL 23.18). Check the wire between the Booklet PWB and the Finisher PWB for an open or short circuit. If the problem continues, replace the Booklet PWB (PL 23.21). Replace the Finisher PWB (PL 23.16). Alternately execute Component Control[013-028 Staple Move Motor IN and Component Control[ 013-029 Staple Move Motor OUT]. The Stapler Move Motor (PL 23.8) starts up. Y↓N→Check the connections of P/J8906, P/J8992 and P/J8896. Connectors are connected correctly. Y↓N→Connect the connectors. Check the wire between J8906 and J8992 for an open circuit or a short circuit. The wire between J8906 and J8992 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the resistance of the Staple Move Motor between each J 8992-1/2/5/6 and each GND. The resistance is approx. 10Ohm. Y↓N→Replace the Staple Move Motor (PL 23.8). Measure the voltage between the Finisher PWB P8985-4 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the Finisher PWB (PL 23.16). Replace the Staple Move Motor (PL 23.8 ). If the problem persists, replace the Finisher PWB (PL 23.16). Replace the Finisher PWB (PL 23.16).