Description: Stapler Feed Ready Failure RAP When starting Staple, Staple Ready Sensor Off was detected. Empty stapling was within 13 times.
Remedy: Execute Component Control[012-243 Staple Ready Sensor]. Install and remove the Staple Cartridge. The display changes. Y↓N→Check the Staple Cartridge for failure or foreign substances. There are no foreign substances and nothing has failed. Y↓N→Repair the failure and remove the foreign substances. Check the connections of J8886 and P/J8981. J8886 and P/J8981 are connected correctly. Y↓N→Connect J8886 and P/J8981. Check the wire between J8886 and J8981 for an open circuit or a short circuit. The wire between J8886 and J8981 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the Finisher PWB P8981-4 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the Finisher PWB (PL 23.16). Measure the voltage between the Finisher PWB P8981-6 (+) and GND (-). Install and remove the Staple Cartridge. The voltage changes. Y↓N→Replace the Finisher PWB (PL 23.16). Replace the Staple Assembly (PL 23.8). If the problem persists, replace the Finisher PWB (PL 23.16). Replace the Finisher PWB (PL 23.16). If the problem persists, replace the MCU PWB (PL 9.1).