Description: OCT 1 RAP the OCT Home Sensor 1 did not actuate in time after the OCT1 Motor energized.
Remedy: Manually operate the offset mechanism. The offset mechanism moves smoothly. Y↓N→Replace the parts that are interfering with operation (PL 6.2). Execute Component Control [047-205 OCT Home Sensor 1]. Actuate the OCT Home Sensor 1 with paper. The display changes. Y↓N→Check the connections of P/J117, P/J613, P/J432. Connections are connected correctly. Y↓N→Connect connectors Check the wire between P/J117 and P/J432 for an open circuit or a short circuit. The wires are conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Replace the OCT Home Sensor 1 (PL 6.2). Alternately execute Component Control [047-001 Offset Motor 1 (CW)] and Component Control [047-005 Offset Motor 1 (CCW)]. The Offset Motor 2 energizes. Y↓N→Check the connections of P/J432 and P/J206. Connections are connected correctly. Y↓N→Connect connectors Check the wire between P/J432 and P/J206 for an open circuit or a short circuit. The wires are conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the resistance of the Offset Motor 1 between J206-1 (COM) and each point of J206- 2/3/4/5. The resistance is approx. 100Ohm. Y↓N→Replace the Offset Motor 1 (PL 6.2). Measure the voltage between the Exit PWB P432-7 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Go to BSD 1.1 and troubleshoot the +24VDC circuit. ReplaReplace the MCU PWB (PL 9.1).ce the Offset Motor 1 (PL 6.2) If the problem persists, replace the MCU PWB (PL 9.1).