Mã lỗi 062-371 — Xerox WorkCentre 5230

Code: 062-371

Description: Lamp Illumination RAP The amount of light from Exposure Lamp is inadequate which gets incident on CCD at the start of scan or at the initialization of IIT after power on.
Remedy: Check the lamp, lens, mirror and the white correcting plate for abnormalities such as contamination and deterioration. Abnormality such as contamination or deterioration of the lamp, lens, mirror or the white correcting plate is found. Y↓N→Replace the lamp, lens, mirror or the white correcting plate. Execute Component Control [062-002 IIT Exposure Lamp]. The Exposure Lamp lights up. Y↓N→Check the connections of P/J703, P/J702 and P/J7231. P/J703, P/J702 and P/J7231 are connected correctly. Y↓N→Connect P/J703, P/J702 and P/J7231. Check the wire between J702 and J7231 for an open circuit or a short circuit. The wire between J702 and J7231 is conducting without an open circuit or a short circuit. Y↓N→Replace the Lamp Wire Harness (PL 11.6). Measure the voltage between the IIT/IPS PWB (PL 13.3) P7231-1 (+) and GND (-), and between P7231-2 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the IIT/IPS PWB (PL 11.3). Replace the Exposure Lamp (PL 11.6) If the problem persists, replace the Lamp Ballast PWB (PL 11.6) If the problem persists, replace the IIT/IPS PWB (PL 13.3). Check the connections of P/J700 and P/J7101. P/J700 and P/J7101 are connected correctly. Y↓N→Connect P/J700 and P/J7101. Replace the Lens Kit Assembly (PL 11.4) If the problem persists, replace the IIT/IPS PWB (PL 11.3).

← Xem tất cả mã lỗi Xerox WorkCentre 5230

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie