Code: 062-380
Description: Platen AGC CH1 RAP At the adjustment of CCD output after power on, CCD does not make a correct output which it should when it receives a specified amount of light.
Remedy: Check the lamp, lens, mirror and the white correcting plate for abnormalities such as contamination and deterioration. Abnormality such as contamination or deterioration of the lamp, lens, mirror or the white correcting plate is found. Y↓N→Replace the lamp, lens, mirror or the white correcting plate. Execute Component Control[062-002 IIT Exposure Lamp]. The Exposure Lamp lights up. Y↓N→Check the connections of P/J703, P/J702 and P/J7231. P/J703, P/J702 and P/J7231 are connected correctly. Y↓N→Connect P/J703, P/J702 and P/J7231. Check the wire between J702 and J7231 for an open circuit or a short circuit. The wire between J702 and J7231 is conducting without an open circuit or a short circuit. Y↓N→Replace the Lamp Wire Harness (PL 11.6). Measure the voltage between the IIT/IPS PWB (PL 13.3) P723-1 (+) and GND (-), and between P723-2 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the IIT/IPS PWB (PL 11.3). Replace the Exposure Lamp (PL 11.6) If the problem persists, replace the Lamp Ballast PWB (PL 11.6) If the problem persists, replace the IIT/IPS PWB (PL 11.3). Check the connections of P/J700 and P/J7101. P/J700 and P/J7101 are connected correctly. Y↓N→Connect P/J700 and P/J7101. Replace the Lens Kit Assembly (PL 11.3) If the problem persists, replace the IIT/IPS PWB (PL 11.3).