Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 077-301 — Xerox WorkCentre 5230

Code: 077-301

Description: Left Hand Interlock Open RAP The L/H Cover Assembly is open.
Remedy: Check opening/closing of the L/H Cover Assembly. The L/H Cover Assembly can be opened/closed. Y↓N→Reinstall the L/H Cover Assembly (PL 2.6). Check the installation of the L/H Cover Interlock Switch. The L/H Cover Interlock Switch is installed correctly. Y↓N→Install the L/H Cover Interlock Switch correctly. Execute Component Control [071-300 L/H Cover Interlock Switch]. Open and close the L/H Cover Assembly. The display changes. Y↓N→Check the connections of P/J120 and P/J405. P/J120 and P/J405 are connected correctly. Y↓N→Connect P/J120 and P/J405. Check the wire between J405 and J120 for an open circuit or a short circuit. The wire between J405 and J120 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Check the conductivity of the L/H Cover Interlock Switch (PL 2.6) between J405-1 and J405-2. The wire between J405-1 and J405-2 is connecting successfully when the L/H Cover Assembly is closed, and is insulated when the cover is open. Y↓N→Replace the L/H Cover Interlock Switch (PL 2.6). Measure the voltage between the MCU PWB P405-2 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Measure the voltage between the MCU PWB P400-1 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Check the connections of P/J526 and P/J400. P/J526 and P/J400 are connected correctly. Y↓N→Connect P/J526 and P/J400. Check the wire between J526 and J400 for an open circuit or a short circuit. The wire between J526 and J400 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Check the connections of P/J521, P/J523 and P/J300, P/J301. P/J521, P/ J523 and P/J300, P/J301 are connected correctly. Y↓N→Connect P/J521, P/J523 and P/J300, P/J301. Check the wire between J521, J523 and J300, J301 for an open circuit or a short circuit. The wire between J521, J523 and J300, J301 are conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the ESS PWB P301-3 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the ESS PWB (PL 9.2). Replace the Power Unit (PL 9.1). Replace the MCU PWB (PL 9.1). Replace the MCU PWB (PL 9.1). Replace the MCU PWB (PL 9.1).

← Xem tất cả mã lỗi Xerox WorkCentre 5230

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie