Mã lỗi 077-309 — Xerox WorkCentre 5230

Code: 077-309

Description: Left Hand Low Interlock Open RAP The L/H Lower Cover is open.
Remedy: Check opening/closing of the L/H Lower Cover. The L/H Lower Cover can be opened/ closed. Y↓N→Reinstall the L/H Lower Cover (PL 2.5). Check the installation of the L/H Lower Cover Interlock Switch. The L/H Lower Cover Interlock Switch is installed correctly. Y↓N→Install the L/H Lower Cover Interlock Switch (PL 2.5) correctly. Execute Component Control [071-302 L/H Lower Cover Interlock Switch]. Open/close the L/H Lower Cover. The display changes. Y↓N→Check the connections of P/J106 and P/J410. P/J106 and P/J410 are connected correctly. Y↓N→Connect P/J106 and P/J410. Check the wire between J106 and J410 for an open circuit or a short circuit. The wire between J106 and J410 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Check the conductivity of the L/H Lower Cover Interlock Switch (PL 2.5) between J410-11 and J410-12. The wire between J410-11 and J410-12 is connecting successfully when the L/H Lower Cover is closed, and is insulated when the cover is open. Y↓N→Replace the L/H Lower Cover Interlock Switch (PL 2.5). Replace the MCU PWB (PL 9.1). Replace the MCU PWB (PL 9.1).