Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 078-300 — Xerox WorkCentre 5230

Code: 078-300

Description: HCF Top Cover Interlock Open RAP BSD-ON: The HCF Top Cover Interlock is open.
Remedy: Execute Component Control [078-300 HCF Top Cover Interlock]. Open and close the Transport Cover. The display changes. Y↓N→+24VDC is measured between JF05-2 on the HCF PWB and GND. Y↓N→+24VDC is measured between JF05-1 on the HCF PWB and GND. Y↓N→+24VDC is measured between JF04-1 on the HCF PWB and GND. Y↓N→Check the +24VDC circuit between the IOT and the HCF PWB. Replace the HCF PWB (PL18.8). Check the wires between JF05-1 on the HCF PWB and FS001 on the HCF Top Cover Interlock Switch, and between FS002 on the HCF Top Cover Interlock Switch and JF05-2 on the HCF PWB for an open wire or poor contact. If the wires are good, replace the HCF Top Cover Interlock Switch (PL 18.7). Replace the HCF PWB (PL 18.8). The problem could be misalignment between the HCF Top Cover and the HCF Top Cover Interlock Switch. Check if the Switch/Cover is improperly installed and if the actuator is broken or bent. If OK, replace the MCU PWB (PL 9.1).

← Xem tất cả mã lỗi Xerox WorkCentre 5230

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie