Description: Drum Cartridge End of Life RAP It is time to replace the Drum Cartridge.
Remedy: Check the Drum Cartridge for failure or foreign substances. There are no foreign substances and nothing has failed. Y↓N→Repair the failure and remove the foreign substances. Check the installation of the XERO CRUM PWB. The XERO CRUM PWB is installed correctly. Y↓N→Install the XERO CRUM PWB correctly (PL 4.2). Check the connection of the MCU PWB P/J419. P/J419 is connected correctly. Y↓N→Connect P/J407. Check the connection of the XERO CRUM PWB P/J126. P/J126 is connected correctly. Y↓N→Connect P/J142. Check the wire between J419 and P1126 for an open circuit or a short circuit. Thwei irse conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the MCU PWB J419-1 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the MCU PWB (PL 9.1). Replace the Drum Cartridge (PL 4.1) If the problem persists, replace the XERO CRUM PWB (PL 4.1) If the problem persists, replace the MCU PWB (PL 9.1).