Description: Xero CRUM Comm RAP There is a failure with communication between the Xero CRUM and MCU PWB.
Remedy: Pull out and reinstall the Xerographics Drum Module. The problem persists. Y↓N→Return to Service Call Procedures. Verify the connections and condition of the circuit between Xero CRUM and MCU PWB. Thcei rcuit is free of damage and the connections are good. Y↓N→Repair the damage as required. Check CRUM operating voltage. The operating voltage is correct. Y↓N→Check the circuit for damage. If the circuit is free of damage replace the MCU PWB (PL 9.1). Enter diagnostics and verify NVM value for Xero CRUM data, location [751-010]. If NVM value indicates failure replace Xerographics Drum Module (PL 4.1) If NVM value indicates no failure, replace the MCU PWB (PL 9.1).