Code: 012-259
Description: (Integrated Finisher) Eject Home Sensor ON Fail RAP In the Eject Motor’s initializing operation and ejecting operation, one of the following is met. • With the Eject Home Sensor Off, the Eject Motor started rotating in reverse direction. Within a specified time after that, the Eject Home Sensor was not detected turning On. • With the Eject Home Sensor Off, the Eject Motor started rotating in reverse direction. The Eject Home Sensor should have been detected turning On and then the Eject Motor stopped, but then the Eject Home Sensor was not On.
Remedy: Check the Eject mechanism for a deformed or broken part and not-seated belts. The mechanism is free from defects and belt damage. Y↓N→Repair the mechanism. Enter Component Control [012-252]. Block and unblock the Eject Home Sensor. The display changes. Y↓N→Check the connections of P/J8700 and P/J8725. P/J8700 and P/J8725 are securely connected. Y↓N→Connect P/J8700 and P/J8725 securely. Check for an open wire or short circuit between P/J8700 and P/J8725. The wire between P/J8700 and P/J8725 is normally conductive with no open wire or short circuit. Y↓N→Repair the open wire or short circuit. Measure the voltage between Finisher PWB P/J8700-9 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Go to Integrated Finisher Wirenets and check the +5VDC circuit. Measure the voltage between Finisher PWB P/J8700-2 (+) and GND (-). Block and unblock the Eject Home Sensor. The voltage changes Y↓N→Replace the Eject Home Sensor (PL 22.10). Check the wires and connectors for an intermittent open or short circuit. If the problem continues, replace the Finisher PWB (PL 22.7). Enter [012-054] and [012-056] alternately. The Eject Motor rotates. Y↓N→Check the connections of P/J8706 and P/J8741. P/J8706 and P/J8741 are securely connected. Y↓N→Connect P/J8706 and P/J8741 securely. Check for an open or short circuit between P/J8706 and P/J8741. The wires between P/J8706 and P/J8741 are OK. Y↓N→Repair the open wire or short circuit. Measure the voltage between Finisher PWB P/J8706-13 (+) and GND (-), and between P/J8706-15 (+) and GND (-). Each voltage is approx. +24VDC. Y↓N→Go to Integrated Finisher Wirenets and check the +24VDC circuit. If the problem continues, replace the Finisher PWB (PL 22.7). Replace the Eject Motor (PL 22.9). If the problem continues, replace the Finisher PWB (PL 22.7). Check the wires and connectors for an intermittent open or short circuit. If the problem continues, replace the Finisher PWB (PL 22.7).