Code: 012-291
Description: (Integrated Finisher) Stapler Fail RAP Within a specified time after the Staple Motor started rotating in reverse direction, the Staple Head Home Sensor was never detected turning On.
Remedy: Enter Component Control [012-046] and [012-047] alternately. The Staple Motor rotates. Y↓N→Check the connections of P/J8705 and P/J8735. P/J8705 and P/J8735 are securely connected. Y↓N→Connect P/J8705 and P/J8735 securely. Check for an open or short circuit between P/J8705 and P/J8735. The wires between P/J8705 and P/J8735 are OK. Y↓N→Repair the open wire or short circuit. Enter [012-046] and [012-047] alternately. Measure the voltages between Finisher PWB P/J8705-3, 4, 5, 6 (+) and GND (-). Each voltage changes. Y↓N→Check the wires and connectors for an intermittent open or short circuit. If the problem continues, replace the Finisher PWB (PL 22.7) Replace the Staple Assembly (PL 22.4). Enter [012-046] and [012-047] alternately. The display changes. Y↓N→Check the connections of P/J8701 and P/J8731. P/J8701 and P/J8731 are securely connected. Y↓N→Connect P/J8701 and P/J8731 securely. Check for an open or short circuit between P/J8701 and P/J8731. The wires between P/J8701 and P/J8731 are OK. Y↓N→Repair the open or short circuit. Measure the voltage between Finisher PWB P/J8701-9 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Go to Integrated Finisher Wirenets and check the +5VDC circuit. Measure the voltage between Finisher PWB P/J8731-5 (+) and GND (-). Enter [012-046] and [012-047] alternately. The voltage changes. Y↓N→Replace the Staple Assembly (PL 22.4). Check the wires and connectors for an intermittent open or short circuit. If the problem continues, replace the Finisher PWB (PL 22.7). Check the wires and connectors for an intermittent open or short circuit. If the problem continues, replace the Finisher PWB (PL 22.7).