Description: Compiler Tray No Paper Sensor Static JAM RAP (LX) Paper remains on the Compiler Tray No Paper Sensor.
Remedy: Enter Component Control [012-151], Compiler Tray No Paper Sensor. Select Start. Actuate the Compiler Tray No Paper Sensor. The display changes. Y↓N→Check the wire between J8880 pin 2 and P/J8994 pin 2 on the Finisher PWB for an open or short circuit, or a loose or damaged connector. The wire is OK. Y↓N→Repair/reconnect as required. Measure the voltage between P/J8994 pins 3 and 1 on the Finisher PWB (BSD 12.19 - Office Finisher LX Tamping & Offset (2 of 2). The voltage is approx. +5VDC. Y↓N→Replace the Finisher PWB (PL 23.16). Measure the voltage between P/J8994 pin 2 on the Finisher PWB and GND (BSD 12.19 - Office Finisher LX Tamping & Offset (2 of 2). Actuate the Compiler Tray No Paper Sensor. The voltage changes. Y↓N→Replace the Compiler Tray No Paper Sensor (PL 23.12). Replace the Finisher PWB (PL 23.16). If the problem continues, replace the Finisher PWB (PL 23.16).