Code: 013-212
Description: Booklet Staple Move Position Sensor On Fail RAP (LX) Booklet Staple Move Position Sensor does not turn on within designated time period
Remedy: Execute Component Control [013-144], Booklet Staple Move Position Sensor. Move the Booklet Stapler to block and unblock the sensor (PL 23.18). The display changes. Y↓N→Check the wire between J8898 pin 2 and P/J8991 pin 5; and the wire between J8984, pin 5 and J8985 pin 5 for an open or short circuit, or a loose or damaged connector. The wires are OK. Y↓N→Repair/reconnect as required. Measure the voltage between P/J8991, pins 6 and 4 on the Booklet PWB. The voltage is approx. +5VDC. Y↓N→Replace the Booklet PWB (PL 23.21). Measure the voltage between P/J8991 pin 5 on the Booklet PWB and GND. Actuate the Booklet Staple Move Position Sensor. The voltage changes. Y↓N→Replace the Booklet Staple Move Position Sensor (PL 23.18). Measure the voltage between J8895 pin 5 on the Finisher PWB and GND. Actuate the Booklet Staple Move Position Sensor. The voltage changes. Y↓N→Replace the Booklet PWB (PL 23.21). If the problem persists, replace the Finisher PWB (PL 23.16). Replace the Finisher PWB (PL 23.16). Alternately execute Component Control [013-028], Stapler Move Motor In and [013-029], Stapler Move Motor Out. The Stapler Move Motor moves. Y↓N→Check the wires between P/J8992 pins 1~6 on the Booklet PWB and P/J8906 on the Booklet Stapler Move Motor for an open or short circuit, or loose or damaged connectors. The wires are OK. Y↓N→Repair/replace as required. Monitor the voltage at J8984, pin 3. Alternately execute Component Control [013-028], Stapler Move Motor In and [013-029], Stapler Move Motor Out. An AC clock pulse is detected. Y↓N→Check the wire between J8984, pin 3 and J8985 pin 4. If the wire is OK, replace the Finisher PWB (PL 23.16). Replace the Booklet Stapler Move Motor (PL 23.18). If the problem persists, replace the Booklet PWB (PL 23.21). Go to BSD 12.25 - Office Finisher Booklet Staple Positioning and check for an intermittent circuit.