Description: Low Staples RAP (Integrated Finisher) Staples Near Empty or Staple-feed failure.
Remedy: Execute Component Control [012-242 Low Staple Sensor]. Install and remove the Staple Cartridge. The display changes. Y↓N→Check the Staple Cartridge for failure or foreign substances. There are no foreign substances and nothing has failed. Y↓N→Repair the failure and remove the foreign substances. Check the wires between P/J8731 and P/J8701 for a loose connection, or an open or a short circuit. The wires are OK. Y↓N→Repair as required. Measure the voltage between the Finisher PWB P/J8701 -5 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the Finisher PWB (PL 22.7). Measure the voltage between the Finisher PWB P/J8701-7 (+) and GND (-). Install and remove the Staple Cartridge. The voltage changes. Y↓N→Replace the Finisher PWB (PL 22.7). Replace the Staple Assembly (PL 22.4) If the problem persists, replace the Finisher PWB (PL 22.7). Check the sw version of the controller sw - update if required. Replace the Finisher PWB (PL 22.7) If the problem persists, replace the MCU PWB (PL 18.2).