Mã lỗi 042-310 — Xerox WorkCentre 5325

Code: 042-310

Description: Main Motor Failure RAP The Main Motor is not rotating at the specified speed.
Remedy: Close the LH Cover and the Front Cover. Execute Component Control [042-003 Main Motor ON]. The Main Motor can be heard. Y↓N→Go to BSD 4.1 - Main Drive Control and the wires between the MCU PWB ( P/J407 and P/J408) and the Main Motor ( P205 and P204) for an open or short circuit. If OK replace the Main Motor (PL 3.2) Check the installation of the Main Drive Assembly (PL 3.1 and PL 3.2). The Main Drive Assembly is installed correctly. Y↓N→Install the Main Drive Assembly correctly. Check the wire between P/J407-9 and P205-8 for an open circuit or a short circuit (BSD 4.1 - Main Drive Control). The wires are conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Manually rotate the Main Motor rotor. It rotates smoothly. Y↓N→Check for foreign substances that are interfering with operation or installation failure. Foreign substances or installation failure are found. Y↓N→Replace the Main Drive Assembly (PL 3.1). Remove the foreign substances that are interfering with operation and correct the installation failure. Replace the Main Drive Assembly (PL 3.1) If the problem persists, replace the MCU PWB (PL 18.2).