Description: Tray 3 Misfeed RAP The Tray 3 Feed Out Sensor does not turn ON within the specified time after the Feed from Tray 3 has started.
Remedy: Remove Tray 3. Turn the power ON and enter the Diag mode. Turn ON Component Control [073-001] (Tray 3 Feed/Lift Motor). Does the Tray 3 Feed/Lift Motor rotate? Y↓N→Go to the +24VDC-2 IOT wirenets. Is the voltage between the Tray Module PWB P/J 541-8 (+) and the GND (-) +24VDC? Y↓N→Go to +24VDC Power RAP. Turn the power OFF, then measure the Tray 3 Feed/Lift Motor wire wound resistance. Check the resistance of the following. • Between the Tray Module PWB P/J555 -1 and P/J555-2 • Between the Tray Module PWB P/J555-3 and P/J555-4 Is the resistance approx. 4Ohm for each? (When the temperature is 25 °C) Y↓N→Check the connection between the Tray Module PWB P/J555 and the Tray 3 Feed/ Lift Motor P/J222 for open circuit, short circuit, and poor contact. If there are no problems, replace the Tray 3 Feed/Lift Motor (PL 11.9). Measure the resistance between the Tray Module PWB P/J555-1/2/3/4 and the Frame. Is the resistance infinite for all? Y↓N→Check the wires of the pins with non-infinite resistance for peeled-off coatings and short circuits due to pinching. Replace the following parts in sequence: • Tray Module PWB (PL 11.13) • MCU PWB (PL 18.2) • Press the Stop button. Turn ON Component Control [077-033] (TM Takeaway Motor).