Code: 077-901
Description: Exit Sensor 1 Static Jam RAP When the power was turned ON, the M/C was stopped (Cycle Down/ Shut Down), or when the interlocks were closed (all interlocks including options), the Fuser Exit Sensor detected paper.
Remedy: Check the following: • The Fuser Exit Sensor for remaining paper, contamination, Actuator return failure, or improper installation • The Fuser Exit Sensor for failure: Component Control [077-101] (PL 7.1) Reload the machine software (GP 16). If no problems are found, replace the MCU PWB (PL 18.2).