Code: 078-250
Description: HCF Lift Fault RAP HCF Tray Lift failure. The Tray 6 Level Sensor does not turn ON within the specified time after the trays were inserted.
Remedy: Open and close Tray 6. The Tray 6 Lift/Feed Motor operates Y↓N→Check the circuit between PF/JF58 on the Tray 6 Lift/Feed Motor and PF/JF 06 on the HCF PWB for an open or a short circuit, or a loose or damaged connector. The wires are OK. Y↓N→Repair as required. Check that the resistance through Tray 6 Lift/Feed Motor is approx. 0.8 ohms at the measurement points below. • PF/JF58-3 to pins 1/2 • PF/JF58-4 to pins 5/6 The resistances are OK+ Y↓N→Replace the Tray 6 Lift/Feed Motor (PL 10.4). There is +24VDC from PF/JF pins 3 and 4, to GND. Y↓N→Go to IOT wirenets and troubleshoot the +24VDC circuit. Replace the Tray 6 Lift/Feed Motor (PL 10.4). If the problem persists, replace the HCF PWB (PL 10.8). Check the installation of the Tray 6 Stack Height Sensor (PL 10.5) and the operation of the actuator. The Stack Height Sensor is installed correctly and the actuator works. Y↓N→Reinstall the Tray 6 Stack Height Sensor. Execute Component Control [078-201], Tray 6 Stack Height Sensor. Manually activate the Tray 6 Stack Height Sensor. The display changes. Y↓N→Check the wires between PF/JF62 on the Tray 6 Stack Height Sensor and PF/JF 102 on the HCF PWB for an open or shorted circuit, or a loose or damaged connector. The wires are OK. Y↓N→Repair as required. There is approx. +5VDC from PF/JF 02 pin 3 to GND. Y↓N→Replace the HCF PWB (PL 10.8). Monitor the voltage between PF/JF62-2 (+) and GND (-) while you activate the actuator of the Tray 6 Stack Height Sensor. The voltage changes. Y↓N→Replace the Tray 6 Stack Height Sensor (PL 10.5). Replace the following the HCF PWB (PL 10.8) Check the mechanical components (PL 10.4) of the lift mechanism for dirty or damaged gears, broken or out-of-place cables. If OK, replace the HCF PWB (PL 10.8).