Code: 093-924
Description: Toner K CRUM Communication Fail RAP Communication failure with Toner CRUM was detected. NOTE: When turning the power OFF, turn OFF the power switch first and then the main power switch. NOTE: The WC 5325/5330/5335 is shipped with “Worldwide Neutral” Toner Cartridges. When the cartridges shipped with the machine are installed, the machine is set to Worldwide Neutral configuration. When the first toner cartridge is replaced in the WC 5325/5330/5335, the Geographic Differentiation Code and Toner Cartridge Type in NVM are automatically changed to the same settings as the replacement cartridge. Once these NVM are set, the WC 5325/5330/5335 toner configuration can only be changed with a CRUM conversion. One or more Toner Cartridges are of the wrong type (i.e., a “Sold” cartridge installed in a “metered” configured machine.
Remedy: 1. Turn the power OFF and ON. 2. Check the connection between the MCU PWB P/J404 and the Toner CRUM PWB P/ J102 for open circuit, short circuit, and poor contact. Also, remove and reinstall the Toner Cartridge and check for improper installation. If no problems are found, replace the following parts in sequence: • Toner Cartridge (PL 8.1) • Toner CRUM PWB (PL 8.2) • MCU PWB (PL 18.2) • Go to the 093-926 Toner CRUM Data Mismatch Fail RAP.