Code: 012-211
Description: (Integrated Finisher) Stacker Tray Fail RAP • Within a specified time after the Stacker Tray started lifting up, the Stack Height Sensor did not detect the lifting up of the Stacker Tray. • Within a specified time after the Stacker Tray started going down at initialization and during a job, the lower position of the tray (Full) could not be detected based on the changes in the Stacker Stack Sensor 1 and the Stacker Stack Sensor 2.
Remedy: Check the drive mechanism to the Stacker Tray for a deformed or broken part and not-seated gears. The mechanism is free from defects and the gears seat properly. Y↓N→Repair the mechanism. Enter Component Control [012-267]. Block and unblock the Stack Height Sensor with a piece of paper. The display changes. Y↓N→Check the connections of P/J8708 and P/J8727. P/J8708 and P/J8727 are securely connected. Y↓N→Connect P/J8708 and P/J8727 securely. Check for an open or short circuit between P/J8708 and P/J8727. The wire between P/J8708 and P/J8727 are OK. Y↓N→Repair the open or short circuit. Measure the voltage between Finisher PWB P/J8708-3 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Go to Integrated Finisher Wirenets and check the +5VDC circuit. Measure the voltage between Finisher PWB P/J8708-2 (+) and GND (-). Block and unblock the Stack Height Sensor with a piece of paper. The voltage changes. Y↓N→Replace the Stack Height Sensor (PL 22.10). Check the wires and connectors for an intermittent open or short circuit. If the problem continues, replace the Finisher PWB (PL 22.7). Enter [012-278]. Block and unblock the Stacker Stack Sensor 1 by rotating the actuator. The display changes. Y↓N→Check the connections of P/J8707 and P/J8722. P/J8707 and P/J8722 are securely connected. Y↓N→Connect P/J8707 and P/J8722 securely. Check for an open or short circuit between P/J8707 and P/J8722. The wires between P/J8707 and P/J8722 are OK. Y↓N→Repair the open or short circuit. Measure the voltage between Finisher PWB P/J8707-6 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Go to Integrated Finisher Wirenets and check the +5VDC circuit. Measure the voltage between Finisher PWB P/J8707-5 (+) and (-). Block and unblock the Stacker Stack Sensor 1 by rotating the actuator. The voltage changes. Y↓N→Replace the Stacker Stack Sensor 1 (PL 22.8). Check the wires and connectors for an intermittent open or short circuit. If the problem continues, replace the Finisher PWB (PL 22.7). Enter [012-279]. Block and unblock the Stacker Stack Sensor 2 by rotating the actuator. The display changes. Y↓N→Check the connections of P/J8707 and P/J8721. P/J8707 and P/J8721 are securely connected. Y↓N→Connect P/J8707 and P/J8721 securely. Check for an open or short circuit between P/J8707 and P/J8721. The wires between P/J8707 and P/J8721 are OK. Y↓N→Repair the open or short circuit. Measure the voltage between Finisher PWB P/J8707-3 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Go to Integrated Finisher Wirenets and check the +5VDC circuit. Measure the voltage between Finisher PWB P/J8707-2 (+) and GND (-). Block and unblock the Stacker Stack Sensor 2 by rotating the actuator. The voltage changes. Y↓N→Replace the Stacker Stack Sensor 2 (PL 22.8). Check the wires and connectors for an intermittent open or short circuit. If the problem continues, replace the Finisher PWB (PL 22.7). Enter [012-060] and [012-061] alternately. The Stacker Motor rotates. Y↓N→Check the connections of P/J8711 and P/J8736. P/J8711 and P/J8736 are securely connected. Y↓N→Connect P/J8711 and P/J8736 securely. Check for an open or short circuit between P/J8711 and P8736. The wires between P/ J8711 and P8736 are OK. Y↓N→Repair the open or short circuit. Enter [012-060], measure the voltage between Finisher PWB P/J8711-1 (+) and GND (- ). The voltage changes. Y↓N→Go to Integrated Finisher Wirenets and check the +24VDC circuit. If the problem continues, replace the Finisher PWB (PL 22.7). Enter [012-061], measure the voltage between Finisher PWB P/J8711-2 (+) and GND (- ). The voltage changes. Y↓N→Go to Integrated Finisher Wirenets and check the +24VDC circuit. If the problem continues, replace the Finisher PWB (PL 22.7). Check the wires and connectors for an intermittent open and short circuit. If the problem continues, replace the Stacker Motor (PL 22.8). Check the wires and connectors for an intermittent open or short circuit. If the problem continues, replace the Finisher PWB (PL 22.7).