Code: 024-912
Description: Tray 3 Size Mismatch RAP Operation Error. Size Mismatch Tray 3: Measured Length Mismatch. When the paper slow scan direction length is measured on the paper path, the length is different from the slow scan length for the size detected by the tray.
Remedy: • Load the correct paper in the tray. If the problem persists, check the sensor using the Generic Sensor Failure RAP. • Ensure that the customer is programming a job within the parameters of the machine utilizing the UI. • The Tray 3 Paper Size Switch for failure: Analog Monitor [073-200];Component Control [073-104] (PL 11.12) • The connection between the Tray 3 Paper Size Sensor P/J102 and the Tray Module PWB P/J548 for open circuit, short circuit, and poor contact • Disconnect then reconnect the IIT, Control Panel, ESS, MCU all PWBs connected to them (RAM, Firmware module, EEPROM) • Check the sw version of the controller sw - update if required (GP 16) • Replace MCU PWB (PL 18.2) • Replace ESS PWB (PL 35.2) (If not fixed by this, reinstall the original ESS & MCU)