Description: HCF Top Cover Interlock Open RAP The HCF Top Cover Interlock is open.
Remedy: Execute Component Control [078-300 HCF Top Cover Interlock]. Open and close the Top Cover. The display changes. Y↓N→+24VDC is measured between PF/JF05-2 on the HCF PWB and GND. Y↓N→+24VDC is measured between PF/JF05-1 on the HCF PWB and GND. Y↓N→+24VDC is measured from PF/JF04 pins 1 and 2 on the HCF PWB to GND. Y↓N→Use BSD 1.7 - DC Power Distribution (options) and the IOT wirenets to troubleshoot the 24 VDC circuit. Replace the HCF PWB (PL 10.8). Check the wires between PF/JF05-1 on the HCF PWB and FS001 on the HCF Top Cover Interlock Switch, and between FS002 on the HCF Top Cover Interlock Switch and PF/JF05-2 on the HCF PWB for an open wire or poor contact. If the wires are good, replace the HCF Top Cover Interlock Switch (PL 10.7). Replace the HCF PWB (PL 10.8). The problem could be misalignment between the HCF Top Cover and the HCF Top Cover Interlock Switch. Check if the Switch/Cover is improperly installed and if the actuator is broken or bent. If the check is good, replace the following in sequence: • HCF PWB (PL 10.8) • MCU PWB (PL 18.2)