Code: 005-915
Description: DADF APS Sensor 1 Static Jam RAP The DADF APS Sensor 1 turns ON at the timings below. 1. When Power is ON 2. At Feeder Cover Interlock Close 3. At Platen Interlock Close
Remedy: Check the following: • Check the DADF APS Sensor 1 for remaining paper, the Actuator for return failure, foreign substances, contamination on sensors, and etc. • DADF APS Sensor 1: Component Control [005-218] (PL 51.17) • Check the sw version of the controller sw - update if required • If the problem persists, check the circuit between the DADF APS Sensor 1 and the DADF PWB. If no problems are found, replace the DADF PWB (PL 51.2).