Code: 012-111
Description: H-Transport Entrance Sensor Off Jam A RAP (LX) The H-Transport Entrance Sensor did not turn off within the specified time after it turned on.
Remedy: Check the H-Transport Drive Rolls (PL 23.4) and Pinch Rolls (PL 23.3) for wear or contamination. Check for obstructions or damage in the paper path. The Paper Path is OK. Y↓N→Clean or replace as required. Execute Component Control [012-190], H-Transport Entrance Sensor. Actuate the H-Transport Entrance Sensor (PL 23.4). The display changes. Y↓N→Check the wire between J8861 pin 2 and J8897 pin 6 for an open or short circuit, or a loose or damaged connector. The wire is OK. Y↓N→Repair/reconnect as required. Measure the voltage between J8897, pins 4 and 5 on the Finisher PWB. The voltage is approx. +5VDC. Y↓N→Replace the Finisher PWB (PL 23.16). Measure the voltage between J8897, pin 6 on the Finisher PWB and GND. Actuate the H-Transport Entrance Sensor. The voltage changes. Y↓N→Replace the H-Transport Entrance Sensor (PL 23.4). Replace the Finisher PWB (PL 23.16). Power OFF. Open the H-Transport Top Cover. Cheat the H-Transport Interlock Sensor. Power ON. The H-Transport Belt rotates. Y↓N→Check the wires between P/J8862 on the H-Transport Motor and J8897 on the Finisher PWB for an open or short circuit, or a loose or damaged connector. The wires are OK. Y↓N→Repair/reconnect as required. Measure the resistance of the H-Transport Motor between each pin P/J8862-1/2/5/6. The resistance is approx. 20 Ohm. Y↓N→Replace the H-Transport Motor (PL 23.4). Replace the Finisher PWB (PL 23.16). If the problem persists, replace the H-Transport Motor (PL 23.4). Check the H-Transport Entrance Sensor and H-Transport Motor circuits for an intermittent condition. If the problem continues, replace the Finisher PWB (PL 23.16).