Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 012-302 — Xerox WorkCentre 5335

Code: 012-302

Description: (Integrated Finisher) Front Cover Interlock OPEN RAP The Front Cover Interlock Open was detected.
Remedy: Check the following; • Front Cover installation • hinges for any damage • Finisher Top Cover Interlock Sensor for any damage Thee above parts are OK. Y↓N→Repair or replace any of the parts that are defected. Enter Component Control [012-302]. Open and close the Front Cover to turn On and Off the Finisher Front Interlock Switch. The display changes. Y↓N→Connect the connections of P/J8702 and P/J8733. P/J8702 and P/J8733 are securely connected. Y↓N→Connect P/J8702 and P/J8733 securely. Check for an open or short circuit between P/J8702 and P/J8733. The wires between P/J8702 and P/J8733 are OK. Y↓N→Repair the open or short circuit. Measure the voltage between Finisher PWB P/J8702-4 (+) and GND (-). Open and close the Front Cover to turn On and Off the Finisher Front Interlock Switch. The voltage changes. Y↓N→Replace the Finisher Front Interlock Switch (PL 22.7). Check the wires and connectors for an intermittent open or short circuit. If the problem continues, replace the Finisher PWB (PL 22.7). Measure the voltage between Finisher PWB P/J8702-1 (+) and (-). The voltage is approx. +24VDC. Y↓N→Go to Integrated Finisher Wirenets and check the +24VDC circuit. Check the wires and connectors for an intermittent open or short circuit. If the problem continues, replace the Finisher PWB (PL 22.7).

← Xem tất cả mã lỗi Xerox WorkCentre 5335

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie