Code: 024-916
Description: Mix Full Stack RAP Any of the following conditions could cause this fault: • The output paper stacked on the Finisher Stacker Tray reaches capacity (for the same paper size only). • The paper size in either the process or cross-process direction of the current job is larger than the top sheet size of the previous job • The top sheet size (width) of previous job is less than 279.4mm and Staple Mode is changed • The top sheet size of the previous job is “unknown”
Remedy: • Go to the 012-212 Stacker Tray Upper Limit Failure RAP (LX) (Office Finisher LX), 012- 211 (Integrated Finisher) Stacker Tray Fail. • Ensure that the customer is programming a job within the parameters of the machine utilizing the UI. • Disconnect then reconnect the IIT, Control Panel, ESS, MCU all PWBs connected to them (RAM, Firmware module, EEPROM) • Check the sw version of the controller sw - update if required • Replace MCU PWB (PL 18.2) • Replace ESS PWB (PL 35.2) (If not fixed by this, reinstall the original ESS & MCU)