Description: Exit 1 OCT Home Fail RAP After the Exit 1 OCT Motor has run for the specified operation time, the Exit 1 OCT Home Position Sensor does not turn ON.
Remedy: Turn the power ON and enter the Diag mode. Turn ON Component Control [077-102] (Exit 1 OCT Home Position Sensor). Move the OCT Chute manually to block/clear the light path to the Exit 1 OCT Home Position Sensor. Does the display change between High/Low? Y↓N→Go to BSD 10.6 - Exit 1 Drive/OCT Control to check the Exit 1 OCT Home Position Sensor (PL 17.1) for an open or short circuit. Press the Stop button. Turn ON Component Control [077-010] and Component Control [077- 011] alternately. Does the OCT 1 Chute move forward and backward? Y↓N→Remove the Rear Lower Cover. Is the voltage between the MCU PWB P/J417-11/12 (+) and the GND (-) +24VDC? Y↓N→Go to +24VDC Power RAP. Turn the power OFF and check the Exit 1 OCT Motor Gear for blockage and the OCT Chute for damage. Also, check the connection between the MCU PWB P/J417 and the Exit 1 OCT Motor P/J217 for open circuit, short circuit, and poor contact. If no problems are found, replace the following parts in sequence: • Exit 1 OCT Motor (PL 17.1) • MCU PWB (PL 18.2) Press the Stop button. Turn the power OFF and replace the MCU PWB (PL 18.2).