Description: Control (Center) Thermistor Over Temperature Failure RAP The Control (Center) Thermistor detected a temperature higher than the specified value.
Remedy: NOTE: When this fault occurs, NVM location 744-005 is set to 1, 2, or 3, depending on the fault. You must reset this location to 0 in order to clear the fault. Check the resistance of the Center Thermistor between J621-5 and J621-1 (BSD 10.1). The resistance is 3k ohms or higher. Y↓N→Replace the Fuser Unit (PL 7.1). Check the Center Thermistor wiring between P/J411 and J621 for an open circuit or a short circuit ( BSD 10.1). The wire between P/J410 and J621 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Replace the Fuser Unit (PL 7.1). If the problem persists, replace the AC Drive PWB (PL 18.2) before replacing the MCU PWB (PL 18.2).