Code: 077-902
Description: Exit Sensor 2 Static Jam RAP When the power was turned ON, the M/C was stopped (Cycle Down/ Shut Down), or when the interlocks were closed (all interlocks including options), the Exit 2 Sensor detected paper.
Remedy: Check the following: • The Exit 2 Sensor for remaining paper, contamination, Actuator return failure, or improper installation • The Exit 2 Sensor for failure: Component Control [077-100] (PL 17.4) • The connection between the Exit 2 Sensor P/J115 and the MCU PWB P/J411 for open circuit, short circuit, and poor contact • The L/H Upper Cover Assembly for damage or mismatch Reload the machine software (GP 16). If no problems are found, replace the MCU PWB (PL 18.2).